EM303B General Purpose Inverter
59
6.2.4
F3 Group: Preset Speed Operation Parameters
No.
Function
Range
Unit Default Type S/N
F3-00
Preset Speed 1
0.00
~
Fmax/0.0
~
Fmax
Hz
0.00
●
96
F3-01
Preset Speed 2
0.00
~
Fmax/0.0
~
Fmax
Hz
5.00
●
97
F3-02
Preset Speed 3
0.00
~
Fmax/0.0
~
Fmax
Hz
10.00
●
98
F3-03
Preset Speed 4
0.00
~
Fmax/0.0
~
Fmax
Hz
15.00
●
99
F3-04
Preset Speed 5
0.00
~
Fmax/0.0
~
Fmax
Hz
20.00
●
100
F3-05
Preset Speed 6
0.00
~
Fmax/0.0
~
Fmax
Hz
25.00
●
101
F3-06
Preset Speed 7
0.00
~
Fmax/0.0
~
Fmax
Hz
30.00
●
102
F3-07
Preset Speed 8
0.00
~
Fmax/0.0
~
Fmax
Hz
35.00
●
103
F3-08
Preset Speed 9
0.00
~
Fmax/0.0
~
Fmax
Hz
40.00
●
104
F3-09
Preset Speed 10
0.00
~
Fmax/0.0
~
Fmax
Hz
45.00
●
105
F3-10
Preset Speed 11
0.00
~
Fmax/0.0
~
Fmax
Hz
50.00
●
106
F3-11
Preset Speed 12
0.00
~
Fmax/0.0
~
Fmax
Hz
50.00
●
107
F3-12
Preset Speed 13
0.00
~
Fmax/0.0
~
Fmax
Hz
50.00
●
108
F3-13
Preset Speed 14
0.00
~
Fmax/0.0
~
Fmax
Hz
50.00
●
109
F3-14
Preset Speed 15
0.00
~
Fmax/0.0
~
Fmax
Hz
50.00
●
110
F3-15
Acceleration Time 2
0.00
~
600.00
S/min 15.00
●
111
F3-16
Deceleration Time 2
0.00
~
600.00
S/min 15.00
●
112
F3-17
Acceleration Time 3
0.00
~
600.00
S/min 15.00
●
113
F3-18
Deceleration Time 3
0.00
~
600.00
S/min 15.00
●
114
F3-19
Acceleration Time 4
0.00
~
600.00
S/min 15.00
●
115
F3-20
Deceleration Time 4
0.00
~
600.00
S/min 15.00
●
116
F3-21
Acceleration/Deceleration Time Unit
0: S
1: min
0
〇
117
F3-22
DC Brake Proportion at Start
0.00
~
30.00,
30.01
~
250.00
%
100.00
〇
118
F3-23
DC Brake Time at Start
0.00
~
30.00
S
0.00
〇
119
F3-24
DC Brake Start Frequency at Stop
0.10
~
60.00/0.1
~
60.0
Hz
2.00
〇
120
F3-25
DC Brake Proportion at Stop
0.00
~
30.00,
30.01
~
250.00
%
100.00
〇
121
F3-26
DC Brake Waiting Time at Stop
0.10
~
30.00
0~15 kW
S
0.40
〇
122
15~110 kW
0.70
110~400 kW
1.00
F3-27
DC Brake Time at Stop
0.00
~
30.00
S
0.00
〇
123
F3-28
Lower Limit Frequency Control
0: Run as per the lower limit
frequency
1: Run at zero speed after
lower limit frequency
running time is up.
0
〇
124
F3-29
Lower Limit Frequency Running Time 0.00
~
600.00
S
60.00
〇
125
F3-30
Open Loop Slip Compensation
0.00
~
200.00
%
100.00
●
126