Data
01H
06H
40H
00H
00H
05H
5CH
09H
Receiving
Sequence
0
1
2
3
4
5
6
7
8
9
Data
01H
06H
40H
00H
00H
05H
5CH
09H
13.8
Troubleshooting of common communication
Set frequency by communication, the inverter trips EED fault.
Cause
:Frequency is changed by communication address 0007H of F0-07, as EEPROM is
frequently stored for more than the erasure times allowed, it gets damaged.
Solution
: For the code frequently modified, please change a2000H of this code.