User Manual
EM303B General Purpose Inverter
78
Fd-19
435
Fd-20
CPUB Software Version X.XX
X.XX
X
436
Fd-21
Inverter Rated Power
0.40~480.00
kW XXXX
X
437
Fd-22
Inverter Rated Voltage
60~660
V
XXX
X
438
Fd-23
Inverter Rated Current
0.1~1500.0
A
XXXX
X
439
Fd-24
Inverter Running Time
User monitoring
HOUR XXXX
X
440
Fd-25
Inverter Running Time
User monitoring
min XXXX
X
441
No.
Function
Range
Unit Default Type S/N
Fd-26
Running Time Control
0:Disabled
1:Enabled
0
-
442
Fd-27
Set Running Time
0
~
65535
HOUR 0
-
443
Fd-28
Distributor Password
444
Fd-29
Manufacturer Password
445
Fd-30
Keypad Software Version X.XX
X.XX
X
446
Fd-31
CPUA Software Version X.XX
X.XX
X
447
7.1.10
FE Group: User Defined Terminal Function Parameters
No.
Function
Range
Unit Default Type S/N
FE-00
Numeric Input Filter Times 0
~
100
;
1=0.50mS
10
〇
448
FE-01
Terminal Input
Positive/Negative Logic
X7 X6
X5 X4 X3
X2 X1
0000000
0
〇
449
0
0
0
0
0
0
0
0: Positive Logic. On at 0V/Off at 24V
1: Negative Logic. Off at 0V/ On at 24V
FE-02
X1 Input Delay Time
0.00
~
300.00
S
0.00
〇
450
FE-03
X2 Input Delay Time
0.00
~
300.00
S
0.00
〇
451
FE-04
Analog Input Signal Options
Ones place: VS input signal options
0: Analog signal input
1: Numeric signal input
Tens place: IS input signal options
0: Analog signal input
1: Numeric signal input
Hundreds place: VF input signal options
0: Analog signal input
1: Numeric signal input
Thousands place: IF input signal options
0: Analog signal input
1: Numeric signal input
0000
〇
452
FE-05
Analog Terminal Input
Logic
Ones place: Input terminal VS
0
:
VS is on at high level input
1
:
VS is onat low level input
Tens place: Input terminal IS
0
:
IS is on at high level input
1
:
IS is on at low level input
Hundreds place: Input terminal VF
0000
〇
453