User Manual
EM303B General Purpose Inverter
52
6
Parameter Table
6.1
Format of Parameter Tables
17 groups of parameter of EM303B: F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, FA, Fb, FC, Fd,
FE, C0, and E0, 32 items in each group.
F0~FE are function setting parameters which consist of two sections.
Section 1: F0~F5, general parameters.
Section 2: F6~FE are advanced parameters.
Group C0 are status monitoring parameters.
Group E0 are fault monitoring parameters.
When F0-27=0, the inverter only displays the parameters of Group F0~F5, C0, and E0.
When F0-27=1, the inverter displays all parameters.
Column 1: the number of the parameter.
Column 2: the function of parameter.
Column 3: the range of parameter.
Column 4: the parameter unit.
Column 5: the parameter default. For instance, XXX represents that the parameter default
varies with the power ratings of inverter.
Column 6: the type of parameter (whether the parameter is editable or not).
Details shown as followings:
“
●
” : Parameter editing is permitted when the inverter is running.
“
〇
” : Parameter editing is prohibited when the inverter is running.
“X”: The parameter is read only.
Unit and Its Abbreviation
HOUR
Hour
m
Meter
%
Percentage
★
SQRT Square Root
min
Minute
mm Millimeter rpm Revolutions per minute
A
Ampere
S
Second
Hz
Her
t
z
MAX
Maximum
V
Voltage
mS
Millisecond kHz Kilohertz MIN
Minimum
SECT
Program
Section
mH
Millihenry kW Kilowatt
bps
Bits per second
★
The basic value of percentage is the rated value.
6.2
Parameter Table
Section 1 General Parameters
6.2.1
F0 Group: General Parameters
No.
Function
Range
Unit
Default
Type
S/N
F0-00
(L)
Speed Reference Input
Monitoring
Torque Reference Input
Monitoring
Frequency: 0.00
~
Fmax/0.0
~
Fmax
Speed: 0
~
F*Customer defined
scaling
Torque input: 0.00~Limited torque
Hz
rpm
%
0.00/0
0.0/0
0.00
X
0
F0-01
(H)
1