User Manual
EM303B General Purpose Inverter
99
terminal is on, then the function of PID regulator conducts positive/negative
function switch. Its function is equivalent to adjusting parameters of F4-05.
Xi=38~43
Not used
Xi=44
Preset current limit terminal 1
Xi=45
Preset current limit terminal 2
Xi=46
Preset current limit terminal 3
When selecting preset current limit, 3 input terminals can be defined as the preset current
limit terminals. Preset current limits set in FA-07
~
FA-13 are selected correspondingly
through programming these 3 terminals. See Table 7-2 for correlation between preset
current limits and the corresponding terminals.
Table 7-2 Correlation between preset current limit and the corresponding terminals
Terminal 3 Terminal 2 Terminal 1
Preset Torque Current
Setting
Corresponding Torque
Current Code
OFF
OFF
OFF
Non-preset Current Limit
Defined by FC-08
OFF
OFF
ON
Preset Current Limit 1
FA-07
OFF
ON
OFF
Preset Current Limit 2
FA-08
OFF
ON
ON
Preset Current Limit 3
FA-09
ON
OFF
OFF
Preset Current Limit 4
FA-10
ON
OFF
ON
Preset Current Limit 5
FA-11
ON
ON
OFF
Preset Current Limit 6
FA-12
ON
ON
ON
Preset Current Limit 7
FA-13
Xi=47
Start wobbulation operation
Wobbulation operation mode starts.
Xi=48
Not used
Xi=49
Program operation reset
When program operation (PLC) is enabled, if the input signal of this terminal is on,
then the program operation time is cleared, and program operation starts from preset
speed 1.
Xi=50
Alternate motor switching command
During running, if input signal of the terminal is on, the inverter regulates the output
according to the parameters of Motor 2.
Xi=51
External fault input
During running, after the terminal receives external device fault signal, inverter stops and
enters fault status. The default is set as NC input by FE-01(Terminal positive/ negative logic).
No.
Function
Range
Unit Default Type
F2-12
Multi-function Output Terminal Y1
See Table7-3
Functions of Numeric
Multi-function Output
Terminals
0
〇
F2-13
Multi-function Output Terminal Y2
1
〇
F2-14
Relay Output Terminal R1
9
〇