User Manual
EM303B General Purpose Inverter
123
Speed Program Operation Mode Selection
F6-00 ones place=0 Monocycle.
Inverter will stop after running as per the time and operation of 7 preset speeds.
F6-00 ones place=1 Run as per Preset Speed 7 after monocycle
Inverter will run as per the preset speed 7 after running as per the time and operation of 7
preset speeds.
F6-00 ones place=2Limited times of continuous cycle
Inverter will run as per the preset speed 1 after running as per the time and operation of 7
preset speeds, and will stop after the cycling operation reached setting times. F6-15 sets the
speed cycling times.
F6-00 ones place=3 Continuous cycle
After running as per the time and operation of 7 preset speeds, inverter will run as per the
preset speed 1. Unless the inverter gets the stop command, it will run from preset speed 1 to
preset speed 7 circularly.
Remarks:
The preset speeds stated here are corresponding to the preset frequencies in F3
Group.
Options of restart after operation paused
F6-00 thousands place=0 Options of restart after operation paused
In the process of program operation, if the external pause input is enabled, power fails or fault
occurs, inverter will re-enter operation status and run as per the preset speed at pause.
F6-00 thousands place=1 Restart from Preset Speed 1
In the process of program operation, if the external pause input is enabled, power fails or fault
occurs, inverter will re-enter operation status and run as per the preset speed 1.
Program operation time unit
F6-00 ten thousands place=0
Program operation time unit: Second
F6-00 ten thousands place =1
Program operation time unit: Minute
8.8.2
Set the Acc./Dec. Time/Mode/Saving Options at Power-Failure for Each Section
No.
Function
Range
Unit Default Typ
e
F6-01
Preset Program
Operation Section 1
Ones place:
Motor running direction options
0: Forward
1: Reverse
Tens place: Options of acceleration
/deceleration time
0: Acceleration / Deceleration time 1
1: Acceleration / Deceleration time 2
2: Acceleration / Deceleration time 3
3: Acceleration / Deceleration time 4
100
〇
F6-02
Preset Program
Operation Section 2
100
〇
F6-03
Preset Program
Operation Section 3
100
〇
F6-04
Preset Program
Operation Section 4
100
〇
F6-05
Preset Program
Operation Section 5
100
〇