User Manual
EM303B General Purpose Inverter
135
Tens place:VF voltage bias options
0: Input / output bias 0
1: Input / output bias 1
2: Input / output bias 2
Hundreds place: IS current bias options
0: Input / output bias 0
1: Input / output bias 1
2: Input / output bias 2
Thousands place: IF current bias options
0: Input / output bias 0
1: Input / output bias 1
2: Input / output bias 2
F8-02
VP Bias
Options
0: Input / output bias 0
1: Input / output bias 1
2: Input / output bias 2
2
〇
On special occasions, user can set a bias curve of analog signal.
Ones place: VS voltage bias options
F8-01 ones place=0/1/2
corresponding to input / output bias 0/1/2
Tens place: VF voltage bias options
F8-01 tens place=0/1/2
corresponding to input / output bias 0/1/2
Hundreds place: IS current bias options
F8-01 hundreds place=0/1/2
corresponding to input / output bias 0/1/2
Thousands place: IF current bias options
F8-01 thousands place=0/1/2
corresponding to input / output bias 0/1/2
VP Bias Options
F8-02 ones place=0/1/2
corresponding to input / output bias 0/1/2
8.10.4
Setting Bias Curve of Analog Setting Signal
No.
Function
Range
Unit
Default
Type
F8-08
Output Bias 0_0 0.00~100.00
%
0.00
●
F8-09
Output Bias 0_1 0.00~100.00
%
25.00
●
F8-10
Output Bias 0_2 0.00~100.00
%
75.00
●
F8-11
Output Bias 0_3 0.00~100.00, 100.00=Fmax %
100.00
●
F8-12
Input Bias 0_0
0.00~ Input Bias 0_1
%
0.00
●
F8-13
Input Bias 0_1
Input Bias 0_0~ Input Bias 0_2
%
25.00
●
F8-14
Input Bias 0_2
Input Bias 0_1~ Input Bias 0_3
%
75.00
●
F8-15
Input Bias 0_3
Input Bias 0_2~100.00
%
100.00
●
F8-08
~
F8-15 set input/output bias 0.
F8-08, F8-09, F8-10, and F8-11
set the output bias of 4 points of user defined bias curve.
They can be set continuously in the range of 0.0%
~
100.0%.
F8-12, F8-13, F8-14, and F8-15
set the analog inputs of 4 points of user defined bias curve.