User Manual
EM303B General Purpose Inverter
161
FE-09
Terminal Y1 Delay Time
0.0
~
600.0
S
0.0
〇
FE-10
Terminal Y1 Pulse Width
0.0
~
600.0
S
5.0
〇
FE-11
Terminal Y2 Delay Time
0.0
~
600.0
S
0.0
〇
FE-12
Terminal Y2 Pulse Width
0.0
~
600.0
S
5.0
〇
FE-13
Terminal R1 Delay Time
0.0
~
600.0
S
0.0
〇
FE-14
Terminal R1 Pulse Width
0.0
~
600.0
S
5.0
〇
Terminal Y1 will be taken as an example to describe the function of terminal delay time. If
setting FE-07 ones place=1, FE-06 ones place selects pulse signal or voltage signal, as shown
in Figure 7-38.
Time T
Voltage V
Terminal
Output
Voltage
Terminal
Output
Pulse
Pulse
Wideband
Control
Program
Input
Delay Time
Figure 7-38 Terminal Output Delay Time
8.15.8
Distinguish Similar Faults
No.
Function
Range
Unit Default Type
FE-20
SC
and
EMC
Faults
Display
0:
SC
Drive failure
1:
EMC
Environment failure
0
X
FE-21
SlU
and
SOFT
Faults
Display
0:
SlU
Stable undervoltage fault
1:
SOFT
Soft-start fault
0
X
FE-22
SCI
/
SPI
/
PID
Faults
Display
0:
SCI
Fault
1:
SPI
Fault
2:PID feedback loss fault
0
X
FE-23
~
FE-31
Not Used
In order to distinguish the faults clearly which are in similar logic or share the same fault
display code, the specific fault type can be confirmed by reviewing the setting value of FE-20,
FE-21, and FE-22.