User Manual
EM303B General Purpose Inverter
75
FA-24
Motor 2
Rotator Resistance R2
0.01
~
60.000
Ω XXXX
〇
345
FA-25
Motor 2 Stator& Rotor
Leakage Inductance Ls
0.1
~
3000.0
mH XXXX
〇
346
FA-26
Motor 2 Stator& Rotor Mutual
Inductance Lm
0.1
~
3000.0
mH XXXX
〇
347
No.
Function
Range
Unit Default Type S/N
FA-27
Motor 2 Efficiency
30.0
~
99.0
%
XXXX
〇
348
FA-28
~
FA-31
Not Used
349
~
351
7.1.7
Fb Group: Not Used
No.
Function
Range
Unit Default Type S/N
Fb-00
~
Fb-31
Not Used
352
~
383
7.1.8
FC Group: Parameters of Operation Control
No.
Function
Range
Unit Default Type S/N
FC-00
Acceleration/
DecelerationMode
0: Linear mode
1: S curve mode
0
〇
384
FC-01
Proportion of
Acceleration S Curve
0.0
~
50.0
% 30.0
〇
385
FC-02
Proportion of
Deceleration S Curve
0.0
~
50.0
% 30.0
〇
386
FC-03
Fan Control
0: Run at power-on
1: Run at start-up
1
〇
387
FC-04
Fan Delay Time
0.00~600.00
S
30.00
●
388
FC-05
Not Used
389
FC-06
Resume previous
working status at
power-on
0: Not Resume
1: Resume
0
〇
390
FC-07
Current Stall Control
0: Disabled
1: Not Used
2: Enabled
2
〇
391
FC-08
Overcurrent Stall Current 50.00
~
180.00
% 150.00
〇
392
FC-09
Current Limit Coefficient
ofWeak Flux
0.20
~
1.00
0.70
393
FC-10
Energy Saving Operation
Options
0: Energy saving operation disabled
1: Energy saving operation enabled
0
〇
394
FC-11
Energy Saving Running
Initial Frequency
10.00
~
600.00/10.0
~
600.0
Hz 20.00
〇
395
FC-12
Energy Current Detecting 20.00
~
80.00
% 40.00
〇
396