![DAP Technology 1394 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/dap-technology/1394/1394_operation-manual_509853091.webp)
Recorder
91
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
details on the right. Those optional details can be enabled and disabled with the right-most button on the
toolbar.
Selecting a packet in the table will display the details of that packet in the (optional) details part and will
also select the corresponding packet or item in all other views of the Recorder.
When clicking with the mouse left of the packet/event type in the table, the packet or event will be
marked/unmarked. See Packet Marking for more information about packet and event marking
Using the Packet Search function, a large number of packets can be marked or unmarked at once, using
matching criteria. See Packet Searching for more information about packet searching.
Using the 'Go to previous marked packet' and or 'Go to next marked packet' buttons, you can easily step
through the marked packets.
By right-clicking on the column headers, a popup window as shown above will appear. The currently
shown packets/events table columns are checked in the menu. A column is shown or hidden by clicking
the corresponding menu item.
The packet/event number column shows the corresponding packet/event number. It is initially hidden and
can be made visible in the packets/events table through the packet/event column menu.
7.4.2. Details
The Packets View displays all packets and events in a list and optionally the details of a selected packet.
It has a toolbar of its own, a table of all the packets/events and an area to the right of the list where the
details of the selected packets can be seen.
7.4.2.1. Toolbar
The Toolbar has the following indicators and buttons:
Go to trigger position
When clicking this button, the cursor is moved to the trigger time. It is only enabled if the trigger position
is defined (trigger occurred during recording).
Go to next Bus Reset
When clicking this button, the next Bus Reset event will be selected. It is only enabled if one or more bus
resets are present (recorded during the recording).
Go to previous packet of same type
When clicking this button, the previous packet of the same type will be selected. It will be enabled if such
Содержание 1394
Страница 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Страница 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Страница 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...