Hardware
436
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
24.4.1.3. FireStealth Front
Polarity led
This dual colored (green/red) led will light up green whenever the FireStealth has participated in the
connection setup of the IEEE 1394b bus and has detected that the polarity of the cable is normal.
This dual colored (green/red) led will light up red whenever the FireStealth has participated in the
connection setup of the IEEE 1394b bus and has detected that the polarity of the cable is inverted.
This dual colored (green/red) led will light up orange whenever the FireStealth has participated in the
connection setup of the IEEE 1394b bus and has detected that the there is no polarity switching inside the
cable although the polarity settings selected in the dialog window of the Data Pickup Logic Connection
Settings are set to inverted.
This dual colored (green/red) led will not light up whenever the FireStealth has not participated in the
connection setup of the IEEE 1394b bus and has not been able to detect any information about the cable
polarity. (This will always be the case whenever configuration of the FireStealth is done after configuration
of the 1394b bus.)
Signal led
This dual colored (green/red) led will light up green whenever the FireStealth has detected that the IEEE
1394b bus is operational.
This dual colored (green/red) led will light up red for 10 milliseconds whenever the FireStealth has
detected a bus reset or an asynchronous packet on the respective port.
This dual colored (green/red) led will light up orange whenever the FireStealth has detected isochronous
packets on the respective port. The intensity of the orange will range from orange to more red the more
isochronous packets are detected on the respective port.
Synchronization led
This green led will light up when the FireStealth has found synchronization to the IEEE 1394b bus.
S100 led
This green led will light up when the line speed of the FireStealth has been set to S100 in the Data Pickup
Logic Connection Settings dialog window.
S200 led
This green led will light up when the line speed of the FireStealth has been set to S200 in the Data Pickup
Содержание 1394
Страница 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Страница 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Страница 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...