Indicators
Triggered indicator
This green indicator will light when the Recorder has been triggered since the last record start.
It has the same status as the 'trigger led' on the Analyzer front panel (see Hardware).
Ready indicator
This green indicator will light when the Recorder has been stopped and has recorded data in its memory
ready for download.
It has the same status as the 'record ready led' on the FireSpy front panel (see Hardware).
Recording indicator
This red indicator will light when recording is in progress. Packets and events will be stored into the
recorder memory when they appear on the IEEE1394 bus and when the Filter logic selects these events
or packets to be stored.
It has the same status as the 'record led' on the Analyzer front panel (see Hardware).
Memory indicators
Record progress bar
This progress bar gives an indication which part of the recorder memory has been filed with packet and
event data. The little vertical line indicates the trigger position. When starting recording, the memory
before this trigger position (left to the trigger position) will be filled with data. If this part of the buffer gets
full, the recording continues throwing away the oldest data and storing the new data (kind of cyclic buffer).
After the Recorder is triggered, the data will be stored after the trigger position (right of the trigger
position). If that part gets full, the Recorder is stopped.
Note that the trigger position within the recorder memory can be changed using the 'Settings' command in
the 'Analyzer' menu. For more information see Settings.
Recorded bytes
This box displays the total stored number of bytes. It will increase during the recording except when the
Recorder is not triggered yet and the memory part before the trigger position is full. In this case old data is
removed when new data is stored and the total number of stored bytes will not change.
Recorder memory size
This box displays the total number of available memory bytes for the Recorder. It can be changed with the
'Settings' command in the 'Analyzer' menu. See Settings for more information.
Triple Analyzers
For triple Analyzers, the Toolbar looks as follows:
It contains the following additional control:
Rec
This control can be used to select the Analyzer nodes to use for recording. Clicking on the "a", "b" or "c"
will activate/deactivate a node. Activated nodes are displayed with a red background color. Deactivated
nodes are indicated with a white background color.
7.1.2.3. Scriptable Export
The Export functionalities have been greatly enhanced by adopting Dap Technology's proven technology:
the scripting features that have been utilized in the Scriptor. The scripting engine for the Export functions
runs on a host computer along with other Analyzer application components while the engine for the
Scriptor runs on a RISC processor embedded on an Analyzer analyzer.
All pre-defined Export options, Packet file, Raw binary file, Text file, CSV file, Hex file, Quadlets file and
Regeneration file, have their own scripts, and depending on the options selected, a different script source
Содержание 1394
Страница 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Страница 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Страница 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...