Generator
150
Copyright © DapTechnology B.V., 2005-2019 - All Rights Reserved., 5/20/2019
Delete
This button can be used to delete the currently selected slot.
Move up
This button can be used to move the currently selected slot one line up. This means that the priority will
be increased by one.
Move down
This button can be used to move the currently selected slot one line down. This means that the priority will
be decreased by one.
Duplicate
This button can be used to insert a copy of the currently selected slot definition.
Import
This button can be used to import slot definitions from a file. See Mil1394SlotExample.csv in the example
directory for an example of such a file.
Ok
This button can be used to commit all changes made to the slot definitions.
Cancel
This button can be used to close the dialog, clearing all changes made to the slot definitions.
Slot Definition table
The center of the dialog contains a table with all the slot definitions that are defined. Each slot is defined
by the following fields.
Enabled
If this field is checked, this slot definition is actually used when generating the packets. If this field is not
checked, this slot definition is discarded on packet generation.
Name
This can be given a user-defined name for the slot definition. This name will also show up in the sequence
editor on the main window of the generator.
Channel
The channel to use for all packets for this slot.
Frame Offset
The offset time relative to the start of the frame (STOF) in microseconds at which al packets in this slot
should be sent. (one per frame)
Jitter
Not implemented yet
Heartbeat
For a selected sequence you can select the 'Auto heartbeat' option in the main window. When selected,
the heartbeat value will increment for each frame. Note that these values are not shown in the packets.
Length
The number of cycles represented in the slot.
Looped
If set to true, the generator will continuously repeat sending the packets for this slot when the end of the
slot is reached.
Triple Analyzers
For triple Analyzers the slot definitions dialog contains an additional node selector as can be seen in the
following picture. Only the slots from the currently selected node are shown. There is a similar node
selector on the Generator window; only the streams from the currently selected node are shown, but all
Содержание 1394
Страница 1: ...1394 Analyzer Operation Manual Hardware and Software Guide Doc DT PRO134MAN700E ...
Страница 11: ...1394AnalyzerOperationManual 11 456 The SCSI2 Connector 457 The SUBD connector ...
Страница 187: ...Scriptor 187 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 199: ...Scriptor 199 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...
Страница 363: ...FormatEditor 363 Copyright DapTechnology B V 2005 2019 All Rights Reserved 5 20 2019 ...