40-49
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 40 Configuring IP Multicast Routing
Configuring Advanced DVMRP Interoperability Features
Figure 40-8
Only Connected Unicast Routes Are Advertised by Default
Beginning in privileged EXEC mode, follow these steps to customize the summarization of DVMRP
routes if the default classful autosummarization does not suit your needs. This procedure is optional.
Note
At least one more-specific route must be present in the unicast routing table before a configured
summary address is advertised.
To remove the summary address, use the
no
ip dvmrp summary-address
address mask
[
metric
value
]
interface configuration command.
Network
Intf
Metric
Dist
176.13.10.0/24 Fa1/0/1 10514432 90
176.32.15.0/24 Fa1/0/2 10512012 90
176.32.20.0/24 Fa1/0/2 45106372 90
Src Network
Intf
Metric Dist
151.16.0/16
Fa1/0/1
7
0
172.34.15.0/24
Fa1/0/1
10
0
202.13.3.0/24
Fa1/0/1
8
0
151.16.0.0/16
m = 39
172.34.15.0/24
m = 42
202.13.3.0/24
m = 40
176.32.10.0/24
m = 1
176.32.15.0/24
m = 1
DVMRP router
Cisco
router
Tunnel
Fast
Ethernet
1/0/1
176.32.10.0/24
Fast
Ethernet
1/0/2
176.32.15.0/24
DVMRP Report
86514
DVMRP Route Table
Unicast Routing Table (10,000 Routes)
interface tunnel 0
ip unnumbered fastethernet1/0/1
interface fastethernet1/0/1
ip addr 176.32.10.1 255.255.255.0
ip pim dense-mode
interface fastethernet1/0/2
ip addr 176.32.15.1 255.255.255.0
ip pim dense-mode
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the interface that is connected to the DVMRP router, and enter
interface configuration command.
Step 3
ip dvmrp summary-address
address
mask
[
metric
value
]
Specify a DVMRP summary address.
•
For
summary-address
address mask
, specify the summary IP
address and mask that is advertised instead of the more specific
route.
•
(Optional) For
metric
value
, specify the metric that is advertised
with the summary address. The default is 1. The range is 1 to 32.
Step 4
end
Return to privileged EXEC mode.
Step 5
show running-config
Verify your entries.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...