5-20
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 5 Managing Switch Stacks
Configuring the Switch Stack
as the stack MAC address, even if the switch is now a stack member and not a stack master. You can also
configure stack MAC persistency so that the stack MAC address never changes to the new stack master
MAC address.
Note
When you enter the command to configure this feature, a warning message appears containing the
consequences of your configuration. You should use this feature cautiously. Using the old stack master
MAC address elsewhere in the domain could result in lost traffic.
Beginning with Cisco IOS Release 12.2(35)SE, you can set the time period as 0 to 60 minutes.
•
If you enter the command with no value, the default delay is 4 minutes. We recommend that you
always enter a value. If the command is entered without a value (the only option prior to this
release), the time delay appears in the running-config file with an explicit timer value of 4 minutes.
•
If you enter
0
, the stack MAC address of the previous stack master is used until you enter the
no
stack-mac persistent timer
command, which immediately changes the stack MAC address to that
of the current stack master. If you do not enter the
no stack-mac persistent timer
command, the
stack MAC address does not change.
•
If you enter a time delay of 1 to 60 minutes, the stack MAC address of the previous stack master is
used until the configured time period expires or until you enter the
no stack-mac persistent timer
command.
If the previous stack master does not rejoin the stack during this period, the switch stack uses the MAC
address of the new stack master as the stack MAC address.
Note
If the entire switch stack reloads, it comes up with the MAC address of the stack master as the stack
MAC address.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...