13-26
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 13 Configuring VLANs
Configuring VLAN Trunks
Load Sharing Using STP Path Cost
You can configure parallel trunks to share VLAN traffic by setting different path costs on a trunk and
associating the path costs with different sets of VLANs, blocking different ports for different VLANs.
The VLANs keep the traffic separate and maintain redundancy in the event of a lost link.
In
Figure 13-4
, Trunk ports 1 and 2 are configured as 100BASE-T ports. These VLAN path costs are
assigned:
•
VLANs 2 through 4 are assigned a path cost of 30 on Trunk port 1.
•
VLANs 8 through 10 retain the default 100BASE-T path cost on Trunk port 1 of 19.
•
VLANs 8 through 10 are assigned a path cost of 30 on Trunk port 2.
•
VLANs 2 through 4 retain the default 100BASE-T path cost on Trunk port 2 of 19.
Step 13
Repeat Steps 7 through 11 on Switch A for a second port in the switch
stack.
Step 14
Repeat Steps 7 through 11 on Switch B to configure the trunk ports
that connect to the trunk ports configured on Switch A.
Step 15
show vlan
When the trunk links come up, VTP passes the VTP and VLAN
information to Switch B. Verify that Switch B has learned the VLAN
configuration.
Step 16
configure terminal
Enter global configuration mode on Switch A.
Step 17
interface gigabitethernet1/ 0/1
Define the interface to set the STP port priority, and enter interface
configuration mode.
Step 18
spanning-tree vlan 8-10 port-priority 16
Assign the port priority of 16 for VLANs 8 through 10.
Step 19
exit
Return to global configuration mode.
Step 20
interface gigabitethernet1/0/2
Define the interface to set the STP port priority, and enter interface
configuration mode.
Step 21
spanning-tree vlan 3-6 port-priority 16
Assign the port priority of 16 for VLANs 3 through 6.
Step 22
end
Return to privileged EXEC mode.
Step 23
show running-config
Verify your entries.
Step 24
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...