42-8
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 42 Configuring Fallback Bridging
Configuring Fallback Bridging
To return to the default path cost, use the
no bridge-group
bridge-group
path-cost
interface
configuration command.
This example shows how to change the path cost to 20 on a port in bridge group 10:
Switch(config)#
interface gigabitethernet2/0/1
Switch(config-if)#
bridge-group 10 path-cost 20
Adjusting BPDU Intervals
You can adjust BPDU intervals as described in these sections:
•
Adjusting the Interval between Hello BPDUs, page 42-8
(optional)
•
Changing the Forward-Delay Interval, page 42-9
(optional)
•
Changing the Maximum-Idle Interval, page 42-9
(optional)
Note
Each switch in a spanning tree adopts the interval between hello BPDUs, the forward delay interval, and
the maximum idle interval parameters of the root switch, regardless of what its individual configuration
might be.
Adjusting the Interval between Hello BPDUs
Beginning in privileged EXEC mode, follow these step to adjust the interval between hello BPDUs. This
procedure is optional.
Step 3
bridge-group
bridge-group
path-cost
cost
Assign the path cost of a port.
•
For
bridge-group
, specify the bridge group number. The range is 1
to 255.
•
For
cost
, enter a number from 0 to 65535. The higher the value, the
higher the cost.
–
For 10 Mbps, the default path cost is 100.
–
For 100 Mbps, the default path cost is 19.
–
For 1000 Mbps, the default path cost is 4.
Step 4
end
Return to privileged EXEC mode.
Step 5
show running-config
Verify your entry.
Step 6
copy running-config startup-config
(Optional) Save your entry in the configuration file.
Command
Purpose
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
bridge
bridge-group
hello-time
seconds
Specify the interval between hello BPDUs.
•
For
bridge-group
, specify the bridge group number. The range is 1
to 255.
•
For
seconds
, enter a number from 1 to 10. The default is 2.
Step 3
end
Return to privileged EXEC mode.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...