21-6
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 21 Configuring Flex Links and the MAC Address-Table Move Update Feature
Configuring Flex Links and MAC Address-Table Move Update
This example shows how to configure the preemption mode as
forced
for a backup interface pair and to
verify the configuration:
Switch#
configure terminal
Switch(conf)#
interface gigabitethernet1/0/1
Switch(conf-if)#
switchport backup interface gigabitethernet1/0/2 preemption mode forced
Switch(conf-if)#
switchport backup interface gigabitethernet1/0/2 preemption delay 50
Switch(conf-if)#
end
Switch#
show interface switchport backup detail
Active Interface Backup Interface State
------------------------------------------------------------------------
GigabitEthernet1/0/21 GigabitEthernet1/0/2 Active Up/Backup Standby
Interface Pair : Gi1/0/1, Gi1/0/2
Preemption Mode : forced
Preemption Delay : 50 seconds
Bandwidth : 100000 Kbit (Gi1/0/1), 100000 Kbit (Gi1/0/2)
Mac Address Move Update Vlan : auto
Configuring the MAC Address-Table Move Update Feature
This section contains this information:
•
Configuring a switch to send MAC address-table move updates
•
Configuring a switch to get MAC address-table move updates
Step 3
switchport backup interface
interface-id
Configure a physical Layer 2 interface (or port channel)
as part of a Flex Links pair with the interface. When one
link is forwarding traffic, the other interface is in standby
mode.
Step 4
switchport backup interface
interface-id
preemption
mode
[
forced
|
bandwidth
|
off
]
Configure a preemption mechanism and delay for a Flex
Link interface pair. You can configure the preemption as:
•
Forced—the active interface always preempts the
backup.
•
Bandwidth—the interface with the higher bandwidth
always acts as the active interface.
•
Off—no preemption happens from active to backup.
Step 5
switchport backup interface
interface-id
preemption
delay
delay-time
Configure the time delay until a port preempts another
port.
Note
Setting a delay time only works with forced and
bandwidth modes.
Step 6
end
Return to privileged EXEC mode.
Step 7
show interface
[
interface-id
]
switchport backup
Verify the configuration.
Step 8
copy running-config startup config
(Optional) Save your entries in the switch startup
configuration file.
Command
Purpose
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...