14-13
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 14 Configuring VTP
Configuring VTP
transparent
VLAN database configuration command to return the switch to VTP server mode. If
extended-range VLANs are configured on the switch, you cannot change VTP mode to server. You
receive an error message, and the configuration is not allowed.
Enabling VTP Version 2
VTP Version 2 is disabled by default on VTP Version 2-capable switches. When you enable VTP
Version 2 on a switch, every VTP Version 2-capable switch in the VTP domain enables Version 2. You
can only configure the version when the switches are in VTP server or transparent mode.
Caution
VTP Version 1 and VTP Version 2 are not interoperable on switches in the same VTP domain. Every
switch in the VTP domain must use the same VTP version. Do not enable VTP Version 2 unless every
switch in the VTP domain supports Version 2.
Note
In TrCRF and TrBRF Token ring environments, you must enable VTP Version 2 for Token Ring VLAN
switching to function properly. For Token Ring and Token Ring-Net media, VTP Version 2 must be
disabled.
For more information on VTP version configuration guidelines, see the
“VTP Version” section on
page 14-9
.
Beginning in privileged EXEC mode, follow these steps to enable VTP Version 2:
To disable VTP Version 2, use the
no vtp version
global configuration command
.
Note
You can also enable VTP Version 2 by using the
vlan database
privileged EXEC command to enter
VLAN database configuration mode and by entering the
vtp v2-mode
VLAN database configuration
command. To disable VTP Version 2, use the
no vtp v2-mode
VLAN database configuration command.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
vtp version 2
Enable VTP Version 2 on the switch.
VTP Version 2 is disabled by default on VTP Version 2-capable switches.
Step 3
end
Return to privileged EXEC mode.
Step 4
show vtp status
In the
VTP V2 Mode
field of the display, verify that VTP Version 2 is enabled.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...