30-9
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 30 Configuring System Message Logging
Configuring System Message Logging
To disable sequence numbers, use the
no service sequence-numbers
global configuration command.
This example shows part of a logging display with sequence numbers enabled:
000019: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36) (Switch-2)
Defining the Message Severity Level
You can limit messages displayed to the selected device by specifying the severity level of the message,
which are described in
Table 30-3
.
Beginning in privileged EXEC mode, follow these steps to define the message severity level. This
procedure is optional.
Note
Specifying a
level
causes messages at that level and numerically lower levels to appear at the destination.
To disable logging to the console, use the
no logging console
global configuration command. To disable
logging to a terminal other than the console, use the
no logging monitor
global configuration command.
To disable logging to syslog servers, use the
no logging trap
global configuration command.
Step 4
show running-config
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
logging console
level
Limit messages logged to the console.
By default, the console receives debugging messages and numerically
lower levels (see
Table 30-3 on page 30-10
).
Step 3
logging monitor
level
Limit messages logged to the terminal lines.
By default, the terminal receives debugging messages and numerically
lower levels (see
Table 30-3 on page 30-10
).
Step 4
logging trap
level
Limit messages logged to the syslog servers.
By default, syslog servers receive informational messages and
numerically lower levels (see
Table 30-3 on page 30-10
).
For complete syslog server configuration steps, see the
“Configuring
UNIX Syslog Servers” section on page 30-12
.
Step 5
end
Return to privileged EXEC mode.
Step 6
show running-config
or
show logging
Verify your entries.
Step 7
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...