26-2
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 26 Configuring CDP
Configuring CDP
CDP and Switch Stacks
A switch stack appears as a single switch in the network. Therefore, CDP discovers the switch stack, not
the individual stack members. The switch stack sends CDP messages to neighboring network devices
when there are changes to the switch stack membership, such as stack members being added or removed.
Configuring CDP
These sections contain this configuration information:
•
Default CDP Configuration, page 26-2
•
Configuring the CDP Characteristics, page 26-2
•
Disabling and Enabling CDP, page 26-3
•
Disabling and Enabling CDP on an Interface, page 26-4
Default CDP Configuration
Table 26-1
shows the default CDP configuration.
Configuring the CDP Characteristics
You can configure the frequency of CDP updates, the amount of time to hold the information before
discarding it, and whether or not to send Version-2 advertisements.
Beginning in privileged EXEC mode, follow these steps to configure the CDP timer, holdtime, and
advertisement type.
Note
Steps 2 through 4 are all optional and can be performed in any order.
Table 26-1
Default CDP Configuration
Feature
Default Setting
CDP global state
Enabled
CDP interface state
Enabled
CDP timer (packet update frequency)
60 seconds
CDP holdtime (before discarding)
180 seconds
CDP Version-2 advertisements
Enabled
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
cdp timer
seconds
(Optional) Set the transmission frequency of CDP updates in seconds.
The range is 5 to 254; the default is 60 seconds.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...