34-4
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 34 Configuring EtherChannels and Link-State Tracking
Understanding EtherChannels
Figure 34-3
Cross-Stack EtherChannel
Port-Channel Interfaces
When you create an EtherChannel, a port-channel logical interface is involved:
•
With Layer 2 ports, use the
channel-group
interface configuration command to dynamically create
the port-channel logical interface.
You also can use the
interface port-channel
port-channel-number
global configuration command
to manually create the port-channel logical interface, but then you must use the
channel-group
channel-group-number
command to bind the logical interface to a physical port. The
channel-group-number
can be the same as the
port
-
channel-number,
or you can use a new number.
If you use a new number, the
channel-group
command dynamically creates a new port channel.
•
With Layer 3 ports, you should manually create the logical interface by using the
interface
port-channel
global configuration command followed by the
no switchport
interface configuration
command. Then you manually assign an interface to the EtherChannel by using the
channel-group
interface configuration command.
For both Layer 2 and Layer 3 ports, the
channel-group
command binds the physical port and the logical
interface together as shown in
Figure 34-4
.
Each EtherChannel has a port-channel logical interface numbered from 1 to 48. This port-channel
interface number corresponds to the one specified with the
channel-group
interface configuration
command.
Switch 1
Catalyst 3750 switch stack
Switch 2
Channel
group 1
StackWise
port
connections
Switch 3
Switch A
86493
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...