18-4
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 18 Configuring STP
Understanding Spanning-Tree Features
Only one outgoing port on the stack root switch is selected as the root port. The remaining switches
in the stack become its designated switches (Switch 2 and Switch 3) as shown in
Figure 18-1 on
page 18-4
.
•
The shortest distance to the root switch is calculated for each switch based on the path cost.
•
A designated switch for each LAN segment is selected. The designated switch incurs the lowest path
cost when forwarding packets from that LAN to the root switch. The port through which the
designated switch is attached to the LAN is called the designated port.
Figure 18-1
Spanning-Tree Port States in a Switch Stack
All paths that are not needed to reach the root switch from anywhere in the switched network are placed
in the spanning-tree blocking mode.
Bridge ID, Switch Priority, and Extended System ID
The IEEE 802.1D standard requires that each switch has an unique bridge identifier (bridge ID), which
controls the selection of the root switch. Because each VLAN is considered as a different
logical bridge
with PVST+ and rapid PVST+, the same switch must have a different bridge IDs for each configured
VLAN. Each VLAN on the switch has a unique 8-byte bridge ID. The 2 most-significant bytes are used
for the switch priority, and the remaining 6 bytes are derived from the switch MAC address.
Switch 1
Catalyst 3750 switch stack
DP
Outgoing RP
Switch 2
RP
StackWise
port
connections
BP
DP
Switch 3
Switch A
Switch B
RP
DP
Spanning-tree root
RP
DP
RP = root port
DP = designated port
BP = blocked port
86491
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...