31-11
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 31 Configuring SNMP
Configuring SNMP
Step 3
snmp-server group
groupname
{
v1
|
v2c | v3
{
auth
|
noauth
|
priv
}} [
read
readview
]
[
write
writeview
]
[
notify
notifyview
] [
access
access-list
]
Configure a new SNMP group on the remote device.
•
For
groupname,
specify the name of the group.
•
Specify a security model:
–
v1
is the least secure of the possible security models.
–
v2c
is the second least secure model. It allows
transmission of informs and integers twice the normal
width.
–
v3,
the most secure, requires you to select an
authentication level:
auth
—Enables the Message Digest 5 (MD5) and the
Secure Hash Algorithm (SHA) packet authentication.
noauth
—Enables the noAuthNoPriv security level. This
is the default if no keyword is specified.
priv
—Enables Data Encryption Standard (DES) packet
encryption (also called
privacy
).
Note
The
priv
keyword is available only when the cryptographic
software image is installed.
•
(Optional) Enter
read
readview
with a string (not to exceed 64
characters) that is the name of the view in which you can only
view the contents of the agent.
•
(Optional) Enter
write
writeview
with a string (not to exceed
64 characters) that is the name of the view in which you enter
data and configure the contents of the agent.
•
(Optional) Enter
notify
notifyview
with a string (not to exceed
64 characters) that is the name of the view in which you
specify a notify, inform, or trap.
•
(Optional) Enter
access
access-list
with a string (not to exceed
64 characters) that is the name of the access list.
Command
Purpose
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...