25-10
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 25 Configuring Port-Based Traffic Control
Configuring Port Security
Table 25-1
shows the violation mode and the actions taken when you configure an interface for port
security.
Default Port Security Configuration
Table 25-2
shows the default port security configuration for an interface.
Port Security Configuration Guidelines
Follow these guidelines when configuring port security:
•
Port security can only be configured on static access ports or trunk ports. A secure port cannot be a
dynamic access port.
•
A secure port cannot be a destination port for Switched Port Analyzer (SPAN).
•
A secure port cannot belong to a Fast EtherChannel or a Gigabit EtherChannel port group.
Note
Voice VLAN is only supported on access ports and not on trunk ports, even though the
configuration is allowed.
Table 25-1
Security Violation Mode Actions
Violation Mode
Traffic is
forwarded
1
1.
Packets with unknown source addresses are dropped until you remove a sufficient number of secure MAC addresses.
Sends SNMP
trap
Sends syslog
message
Displays error
message
2
2.
The switch returns an error message if you manually configure an address that would cause a security violation.
Violation
counter
increments
Shuts down port
protect
No
No
No
No
No
No
restrict
No
Yes
Yes
No
Yes
No
shutdown
No
Yes
Yes
No
Yes
Yes
Table 25-2
Default Port Security Configuration
Feature
Default Setting
Port security
Disabled on a port.
Sticky address learning
Disabled.
Maximum number of secure
MAC addresses per port
1.
Violation mode
Shutdown. The port shuts down when the maximum number of
secure MAC addresses is exceeded.
Port security aging
Disabled. Aging time is 0.
Static aging is disabled.
Type is absolute.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...