40-27
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 40 Configuring IP Multicast Routing
Configuring Advanced PIM Features
To return to the default setting, use the
no ip pim spt-threshold
{
kbps
|
infinity
} global configuration
command.
Modifying the PIM Router-Query Message Interval
PIM routers and multilayer switches send PIM router-query messages to find which device will be the
DR for each LAN segment (subnet). The DR is responsible for sending IGMP host-query messages to
all hosts on the directly connected LAN.
With PIM DM operation, the DR has meaning only if IGMPv1 is in use. IGMPv1 does not have an IGMP
querier election process, so the elected DR functions as the IGMP querier. With PIM SM operation, the
DR is the device that is directly connected to the multicast source. It sends PIM register messages to
notify the RP that multicast traffic from a source needs to be forwarded down the shared tree. In this
case, the DR is the device with the highest IP address.
Beginning in privileged EXEC mode, follow these steps to modify the router-query message interval.
This procedure is optional.
To return to the default setting, use the
no ip pim query-interval
[
seconds
] interface configuration
command.
Step 4
end
Return to privileged EXEC mode.
Step 5
show running-config
Verify your entries.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Command
Purpose
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
interface
interface-id
Specify the interface to be configured, and enter interface configuration
mode.
Step 3
ip pim query-interval
seconds
Configure the frequency at which the switch sends PIM router-query
messages.
The default is 30 seconds. The range is 1 to 65535.
Step 4
end
Return to privileged EXEC mode.
Step 5
show ip igmp interface
[
interface-id
]
Verify your entries.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...