13-30
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 13 Configuring VLANs
Configuring VMPS
•
Trunk ports cannot be dynamic-access ports, but you can enter the
switchport access vlan dynamic
interface configuration command for a trunk port. In this case, the switch retains the setting and
applies it if the port is later configured as an access port.
You must turn off trunking on the port before the dynamic-access setting takes effect.
•
Dynamic-access ports cannot be monitor ports.
•
Secure ports cannot be dynamic-access ports. You must disable port security on a port before it
becomes dynamic.
•
Private VLAN ports cannot be dynamic-access ports.
•
Dynamic-access ports cannot be members of an EtherChannel group.
•
Port channels cannot be configured as dynamic-access ports.
•
A dynamic-access port can participate in fallback bridging.
•
The VTP management domain of the VMPS client and the VMPS server must be the same.
•
The VLAN configured on the VMPS server should not be a voice VLAN.
Configuring the VMPS Client
You configure dynamic VLANs by using the VMPS (server). The switch can be a VMPS client; it cannot
be a VMPS server.
Entering the IP Address of the VMPS
You must first enter the IP address of the server to configure the switch as a client.
Note
If the VMPS is being defined for a cluster of switches, enter the address on the command switch.
Beginning in privileged EXEC mode, follow these steps to enter the IP address of the VMPS:
Note
You must have IP connectivity to the VMPS for dynamic-access ports to work. You can test for IP
connectivity by pinging the IP address of the VMPS and verifying that you get a response.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
vmps server
ipaddress
primary
Enter the IP address of the switch acting as the primary VMPS server.
Step 3
vmps server
ipaddress
(Optional) Enter the IP address of the switch acting as a secondary VMPS
server.
You can enter up to three secondary server addresses.
Step 4
end
Return to privileged EXEC mode.
Step 5
show vmps
Verify your entries in the
VMPS Domain Server
field of the display.
Step 6
copy running-config startup-config
(Optional) Save your entries in the configuration file.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...