28-7
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 28 Configuring SPAN and RSPAN
Understanding SPAN and RSPAN
A source port has these characteristics:
•
It can be monitored in multiple SPAN sessions.
•
Each source port can be configured with a direction (ingress, egress, or both) to monitor.
•
It can be any port type (for example, EtherChannel, Fast Ethernet, Gigabit Ethernet, and so forth).
•
For EtherChannel sources, you can monitor traffic for the entire EtherChannel or individually on a
physical port as it participates in the port channel.
•
It can be an access port, trunk port, routed port, or voice VLAN port.
•
It cannot be a destination port.
•
Source ports can be in the same or different VLANs.
•
You can monitor multiple source ports in a single session.
Source VLANs
VLAN-based SPAN (VSPAN) is the monitoring of the network traffic in one or more VLANs. The SPAN
or RSPAN source interface in VSPAN is a VLAN ID, and traffic is monitored on all the ports for that
VLAN.
VSPAN has these characteristics:
•
All active ports in the source VLAN are included as source ports and can be monitored in either or
both directions.
•
On a given port, only traffic on the monitored VLAN is sent to the destination port.
•
If a destination port belongs to a source VLAN, it is excluded from the source list and is not
monitored.
•
If ports are added to or removed from the source VLANs, the traffic on the source VLAN received
by those ports is added to or removed from the sources being monitored.
•
You cannot use filter VLANs in the same session with VLAN sources.
•
You can monitor only Ethernet VLANs.
VLAN Filtering
When you monitor a trunk port as a source port, by default, all VLANs active on the trunk are monitored.
You can limit SPAN traffic monitoring on trunk source ports to specific VLANs by using VLAN
filtering.
•
VLAN filtering applies only to trunk ports or to voice VLAN ports.
•
VLAN filtering applies only to port-based sessions and is not allowed in sessions with VLAN
sources.
•
When a VLAN filter list is specified, only those VLANs in the list are monitored on trunk ports or
on voice VLAN access ports.
•
SPAN traffic coming from other port types is not affected by VLAN filtering; that is, all VLANs are
allowed on other ports.
•
VLAN filtering affects only traffic forwarded to the destination SPAN port and does not affect the
switching of normal traffic.
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...