43-9
Catalyst 3750 Switch Software Configuration Guide
OL-8550-02
Chapter 43 Troubleshooting
Recovering from a Command Switch Failure
You can prepare for a command switch failure by assigning an IP address to a member switch or another
switch that is command-capable, making a note of the command-switch password, and cabling your
cluster to provide redundant connectivity between the member switches and the replacement command
switch. These sections describe two solutions for replacing a failed command switch:
•
Replacing a Failed Command Switch with a Cluster Member, page 43-9
•
Replacing a Failed Command Switch with Another Switch, page 43-11
These recovery procedures require that you have physical access to the switch.
For information on command-capable switches, see the release notes.
Replacing a Failed Command Switch with a Cluster Member
To replace a failed command switch with a command-capable member in the same cluster, follow these
steps:
Step 1
Disconnect the command switch from the member switches, and physically remove it from the cluster.
Step 2
Insert the member switch in place of the failed command switch, and duplicate its connections to the
cluster members.
Step 3
Start a CLI session on the new command switch.
You can access the CLI by using the console port or, if an IP address has been assigned to the switch, by
using Telnet. For details about using the console port, see the switch hardware installation guide.
Step 4
At the switch prompt, enter privileged EXEC mode:
Switch>
enable
Switch#
Step 5
Enter the password of the
failed command switch
.
Step 6
Enter global configuration mode.
Switch#
configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Step 7
Remove the member switch from the cluster.
Switch(config)#
no cluster commander-address
Step 8
Return to privileged EXEC mode.
Switch(config)#
end
Switch#
Содержание 3750G - Catalyst Integrated Wireless LAN Controller
Страница 80: ...1 28 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 1 Overview Where to Go Next ...
Страница 606: ...27 8 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 27 Configuring UDLD Displaying UDLD Status ...
Страница 670: ...31 18 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 31 Configuring SNMP Displaying SNMP Status ...
Страница 1048: ...41 20 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 41 Configuring MSDP Monitoring and Maintaining MSDP ...
Страница 1086: ...43 26 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Chapter 43 Troubleshooting Using the crashinfo Files ...
Страница 1104: ...B 4 Catalyst 3750 Switch Software Configuration Guide OL 8550 02 Appendix B Supported MIBs Using FTP to Access the MIB Files ...