23. Ensure all excess urethane adhesive is cleaned from the body before water test.
Note: Do not direct a hard stream of high pressure water to the freshly applied urethane adhesive.
24. Use a soft spray of warm water in order to immediately water test the window.
25. Inspect the window for leaks.
26. If any leaks are found, use a plastic paddle in order to apply extra urethane adhesive at the leak point.
27. Retest the window for leaks.
Warning: Insufficient curing of urethane adhesive may allow unrestrained occupants to be ejected from the vehicle resulting
in personal injury.
• For the moisture-curing type of urethane adhesive, allow a minimum of 6
hours at 21°C (70°F) or greater and with at
least 30 percent relative humidity. Allow at least 24
hours for the complete curing of the urethane adhesive.
• For the chemical-curing type of urethane adhesive, allow a minimum of 1
hour .
Do NOT physically disturb the repair area until after these minimum times have elapsed.
28. Maintain the following conditions in order to properly cure the urethane adhesive:
• Partially lower a door window in order to prevent pressure buildups when closing doors before the urethane adhesive
cures.
• Do not drive the vehicle until the urethane adhesive is cured. Refer to the above curing times.
• Do not use compressed air in order to dry the urethane adhesive.
29. Complete the window installation.
Fixed and Movable Windows
BODY SYSTEMS
0-4
BACK TO CHAPTER INDEX
TO MODEL INDEX
CHEVROLET SONIC 2012 BODY REPAIR MANUAL