9-6
Parameters
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
A101 Feed Constant
0100.0000
Feed Constant in IU
Note:
This is where the IU is defined
IU = Input Unit
This parameter describes the conversion from rotary to linear motion. It is
defined as the linear displacement of the load during one revolution of the
gear output shaft.
Input min.:
0.1000
IU
Input max.:
5000.0000
IU
A102 Gearing
0001 0001
Output Revolutions of the Load Gear
Input Revolutions of the Load Gear
A mechanical gear is often employed between the motor and the load.
The gear ratio is defined as:
Gear
Load
of
volutions
Re
Output
Gear
Load
of
volutions
Re
Input
i
=
Fig. 9-2:
Gear Ratio
See also functional description for: "Gear Ratio" and "Modulo Function"
Example:
Five turns of the motor shaft equal two turns of the output shaft.
⇒
Input Revolutions: 5
Output Revolutions: 2
Input min.:
1
Input max.:
9999
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......