Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C218 Feedback 2 data reading error
If the measurement system to be initialized has an intrinsic memory, this
memory is read when the manual/automatic operating mode is switched
on. The C218 Feedback 2 data reading error message is generated if an
additional optional encoder (encoder 2) is present and being evaluated
(Parameter C004, Interface, feedback 2 is not set to "0"), and if an error
is discovered while reading the data.
Measurement systems with intrinsic data memory are :
•
DSF/HSF/LSF and resolvers, as well as
•
Measurement systems with the EnDat interface (from Heidenhain)
Cause:
1.
Defective measurement system cable.
2.
Defective measurement system.
Remedy:
For 1.
Check the measurement system cable.
For 2.
Replace measurement system.
C220 Feedback 1 initializing error
A number of tests are performed when the motor encoder is initialized. An
error was detected during this process. This error may be:
•
an error reading the angle rectification data
•
an error copying the angle rectification data
•
interruption of communications with the encoder
•
an assembly error regarding the position of an initialization track
•
an error reading the analog signals of an initialization track
•
an error in the pointer length for the analog signals of an initialization
track
•
an invalid offset between the high- and low-resolution tracks
•
Error in the measurement system micro-controller
Cause:
1.
Defective motor feedback cable.
2.
Motor encoder defective.
3.
Defective measurement system interface
Remedy:
For 1.
Check the motor feedback cable.
For 2.
Replace the motor.
For 3.
Replace the measurement system interface if it is a module, or
the complete drive controller.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......