8-46
Functions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
If the step response displays the same behavior, then:
⇒
Check the resonance frequency analysis.
- or -
⇒
Increase the value of CR06, Rejection bandwidth velocity loop by a
much larger amount.
⇒
Using the pre-optimized values for CR05, Rejection frequency
velocity loop and CR06, Rejection bandwidth velocity loop,
optimize the velocity loop again (see above).
The step response defined above must have a similar appearance
with higher values for CR02, Velocity loop proportional gain and/or
smaller values for CR03, Velocity loop integral action time.
⇒
Any additional optimization cycles for CR05, Rejection frequency
velocity loop and CR06, Rejection bandwidth velocity loop must
be based on the step response.
⇒
Using a notch (band suppression) filter for optimization of the control
loop does not always produce enough improvement in the control
quality. This can happen, for example, when the closed loop has no
salient resonance frequencies. In some situations, activation of a
second smoothing filter (with low pass response) can nevertheless
produce the desired improvement in the control quality.
⇒
To activate this second filter, set parameter CR06, Rejection
bandwidth velocity loop to "-1." The notch filter and the associated
parameter CR05, Rejection frequency velocity loop are deactivated.
Instead of the notch filter, a smoothing filter is activated in the control
loop. This filter has the same smoothing time constant (T
gl
) as the
smoothing filter in CR04 Velocity loop smoothing time constant.
Together with the smoothing filter at the velocity loop input, a low pass
filter of the 2nd order (2 poles) is produced. Frequencies greater than
the cut-off frequency (f
g
= 1/2
π
T
gl
) are much more heavily suppressed
and can no longer induce oscillations in the control loop.
The parameter for the filter is set via CR04, Velocity loop smoothing
time constant.
Sv5053f1_AE.WMF
Fig. 8-25: Frequency Response of Low Pass Filters with 1 Pole and with 2 Poles
Note:
This setting is made as described in the section entitled:
"Determination of the critical proportional gain and parameter
CR04, Velocity loop smoothing time constant."
Optimize Rejection Filter or
Velocity Loop
Filtering with Two Smoothing
Filters
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......