ECODRIVE03-FL*-04VRS
Functions
8-61
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
All NC commands using Variables V500-V507 or V510-V517, are
executed in their indexed form.
If access to a variable outside of the range V600 to V999 is made,
(besides system variables), the error message "F- 02 23 – Wrong
variable index" is issued.
If these variables are written via the serial interface, fieldbus or using the
SET command, they are written without an index (directly).
Example 1:
SET
V500
=
600
Basic Variable 1 "Length“
SET
V501
=
601
Basic Variable 2 "Velocity“
SET
V502
=
602
Basic Variable 3 "Acceleration“
SET
V503
=
603
Basic Variable 4 "Preset Count“
SET
V504
=
604
Basic Variable 5 "Actual Quantity“
SET
V508
=
5
Number of variables per product
SET
V600
=
15
Product 1
Length
SET
V601
=
800
Product 1
Velocity
SET
V602
=
750
Product 1
Acceleration
SET
V603
=
120
Product 1
Preset Count
SET
V605
=
20
Product 2
Length
SET
V606
=
700
Product 2
Velocity
SET
V607
=
600
Product 2
Acceleration
SET
V608
=
150
Product 2
Preset Count
SET
V610
=
10
Product 3
Length
SET
V611
=
990
Product 3
Velocity
SET
V612
=
400
Product 3
Acceleration
SET
V613
=
100
Product 3
Preset Count
Index
V509
Length
V500
Velocity
V501
Acceleration
V502
Preset Count
V503
Actual Count
V504
0
V600
V601
V602
V603
V604
1
V605
V606
V607
V608
V609
2
V610
V611
V612
V613
V614
3
V615
V616
V617
V618
V619
Fig. 8-38: Product Table, Example 1
The quantity of product-specific data is limited to 8, and the number of
products is limited by the variable field V600 – V999.
SET
V509
= 2
Select Product 3
ACC 1 V502 999
Í
ACC 1 V612 999
Í
ACC 1 400 999
PSI 1 +V500 V501
Í
PSI 1 V610 V611
Í
POI 1 +010 990
COU +00000 Q0.01.3 V503
Í
COU +00000 Q0.01.3 V613
Í
COU +00000 Q0.01.3 100
It follows that:
The value for acceleration is calculated from Variable
# 602+2*5 = 612.
The value for length is calculated from Variable
# 600+2*5 = 610.
The value for velocity is calculated from Variable
# 601+2*5 = 611.
The value for the target quantity is calculated from Variable
# 603+2*5 = 613.
The current actual quantity can be found in Variable
# 604+2*5 = 614.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......