9-36
Parameters
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
B005 Analog Output 1, Scaling per 10V Full Scale
00001.0000
Scaling / Bit Number
The resolution of the selected signal can be varied using Parameter
B005, Analog Output 1 Scaling per 10V Full Scale. If a number is
assigned via B003, Analog Output 1, Signal Select, scaling always uses
the same unit as the parameter with the assigned ID number. When pre-
defined signals are output, scaling is defined as a factor having 4 decimal
places. It has a permanent reference with a fixed unit. Scaling defines the
least significant bit for bit and byte output. The input is an integer value
without decimal places.
B006 Analog Output 2, Signal Select
S 0 0001
Signal Number
S 0 0000 = unassigned
The B006 parameter can be used to assign a signal number to the analog
AK2 output channel of the drive controller.
The content of these signals can be viewed using an oscilloscope.
Input
Definition
B008 Input Value
Value at 10V
S 0 0036
Command Velocity
Contents of Parameter
A106 x 6
Contents of Parameter
A106 [IU/s]
S 0 0040
Actual Velocity
Contents of Parameter
A106 x 6
Contents of Parameter
A106 [IU/s]
S 0 0047
Command Position
IU with
4 Decimal Places
Value from B005
[IU]
S 0 0051
Actual Position, Encoder 1
IU with
4 Decimal Places
Value from B005
[IU]
S 0 0053
Actual Position, Encoder 2
IU with
4 Decimal Places
Value from B005
[IU]
S 0 0080
Command Torque/Force
0.500 = 500%
Current at Standstill,
Parameter CM02
S 0 0084
Actual Torque/Force
0.500 = 500%
Current at Standstill,
Parameter CM02
S 0 0189
Lag Distance
IU with
4 Decimal Places
Value from B005
[IU]
S 0 0347
Velocity Control Deviation
Contents of Parameter
A106 x 6
Contents of Parameter
A106 [IU/s]
S 0 0383
Motor Temperature
0000.1000
100° C
P 0 0098
Max. Model Deviation
IU with
4 Decimal Places
Value from B005
[IU]
P 0 0141
Thermal Controller Load
0000.0100
100%
P 0 4044
Braking Resistor Load
0000.0100
100%
Fig. 9-17: Signal Selection
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......