9-30
Parameters
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
AA19 Press: Time Monitoring
99 M2.02.2
Output Bit: "Timeout – Time expired.“
M2, M3, M4
EMD
: Q3.00.0-Q3.03.7
DKC21.3 : Q0.00.4-Q0.01.3
DKC 3.3 : Q2.02.0-Q2.05.7
Timeout in min.
00 = function inactive
Note:
The input bit "Press" in Parameter AA12 must be
programmed.
The press motion is tested using the falling edge of the feed angle (A116
Feed Angle Monitoring). In Automatic Mode and for the input bit "Press"
(AA12) = 1, the 1
Å
0 edge is monitored. If this edge does not transition
during the timeout preselected in the parameter, the following diagnostic
is issued: "A- 00 12 – Press Timeout" and the output bit programmed in
Parameter AA19 is set.
Via the function "Clear Error," the diagnostic and the output bit are
cleared. Thereafter, time monitoring restarts.
The following conditions clear the diagnostic and the output bit:
Fault, Manual Mode, NC Stop
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......