10-34
Interface
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Status 01
Transmission error, interface
The control sends this status information automatically if an error occurs
in the transmission. Status 01 can not be queried.
In the event of a transmission error, the control delivers the following
message:
X s 0 1 _ f f _ t t t t t t t t t t t t t t t t t t t t _ $ h h C R L F
Meaning of the characters used:
f
= Fault (error) number
t
= Fault (error) text (always 20 characters)
Below is a list of the fault (error) numbers and their meanings:
Faults
No.
Fault Text
Description
01
RS Instruction # Wrong
Incorrect characters in the instruction number. The transmitted instruction number is
not a decimal number.
02
RS Format Error
The format of the transmitted data is incorrect
03
RS Instruction Data Error
The transmitted instruction data are incorrect.
04
RS Checksum Error
The transmitted checksum is incorrect.
05
Invalid Mode
Attempt was made to transmit parameter data. The control was not in `Parameter´
operating mode at the time.
06
Wrong RS Param #
The transmitted parameter number is not a decimal number.
07
Param. # too large
The transmitted parameter number is too large.
08
Wrong RS Status #
The number given in a status request is not a decimal number.
09
Status # illegal
An attempt was made to query status information that was not present.
11
Invalid Param. Block
Incorrect parameter instruction identifier.
12
Instruction # too large
The transmitted instruction number is greater than 999.
13
Invalid Prg Command
An illegal command was transmitted.
16
Value too large
Some of the data is too large. Please note the maximum values in the description
17
Value too small
Some of the data is too small. Please note the minimum values in the description
18
Not accepted!
a) No digit for writing NC commands or parameters.
b) Incorrect data for writing variables.
c) Incorrect source type for Status 61.
d) Unknown interface command.
20
RS system error #1
21
RS system error #2
22
MF para. Read only
Motor Feedback Parameter is not writable
23
Var. No. incorrect
The variable number is not enabled (e.g. unknown system variable)
24
RS system error #3
25
Invalid Operand
Illegal Source/Target Operand in the Logic Task Command
26
Write disabled
Write Protection Active for NC / Logic Task Instructions
28
Indicated Variables No.
Access to Invalid Target Variables Using Index Variables
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......