ECODRIVE03-FL*-04VRS
Parameters
9-61
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
CM02 Motor Peak Current / Stall Current
0023.0 0005.1
Stall Current [A]
Peak Current [A]
The “Motor Peak Current” specifies the maximum current which may
flow through the motor for a short period without damaging it.
If the motor's peak current is less than the amplifier's peak current, the
maximum output current will be automatically limited to the motor's peak
current.
This value is stored in the motor feedback memory of MHD, MKD and
MKE motors and is loaded from there when the drive controller is turned
on for the first time. For other motor types, the value must be taken from
the data sheet.
Input min.:
0.1
A
Input max.:
500.0
A
The “Continuous Motor Stall Current” is the current at which the motor
continuously generates standstill torque according to the motor data
sheet. This value is stored in the motor feedback memory for MHD, MKD
and MKE motors and is loaded from there when the drive controller is
turned on for the first time. For other motor types, the value must be taken
from the data sheet.
All torque/force data are based on this motor stall current being equal
to 100% .
Input min.:
0.1
A
Input max.:
500.0
A
CM03 Maximum Motor Speed
10500.000
in RPM
for rotary motors
m/min
for linear motors
The maximum motor speed should not be exceeded. It also limits
Parameter A106, Maximum Velocity.
This value is stored in the motor feedback memory of MHD, MKD and
MKE motors and is loaded from there when the drive controller is turned
on for the first time. For other motor types, the value must be taken from
the data sheet.
In torque regulation, the drive will be switched to a torque-free state and
the error message F879 Velocity limit exceeded will be issued if the
maximum motor speed is exceeded by more than 12.5%.
Input min.:
0
Input max.:
99999.999
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......