12-64
Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
E- 0106 Jog, Position < Limit
Reverse jogging is not possible. The ’negative position limit value’ has
been reached or exceeded.
Remedy:
Move the axis with the signal ’jog forward’ into the motion range.
E- 0107 Jog, Position > Limit
Forward jogging is not possible. The ’positive position limit value’ has
been reached or exceeded.
Remedy:
Move the axis with the signal ’jog reverse’ into the motion range.
E- 0108 IDS01 – Timeout
The Interface to the IDS-01 decade switch is interrupted.
Cause:
•
IDS-01 Power Supply.
•
Cable
Connection.
•
Parameter settings for the Interface.
E- 0109 Load default values
Default values are loaded. Triggered by S1 probe with the Address 97-99
or via an interface command.
E- 0110 Jog, no power
In Manual Mode, one of the inputs ’Jog forward’ or ’Jog reverse’ was
applied when the power was off.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......