12-58
Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
F- 0308 AT Failure
The initialization of communication between the drive and NC is not o.k.
Cause:
•
Data
loss.
•
Firmware update was executed. Previously, a different firmware or a
different version was loaded.
Remedy:
If possible, pre-select Parameter Mode and clear the error message.
Using S1, S2, and S3 on the programming module, execute a ’Load
parameters with default values.’ (See Chapter 4 ’S1 Key on Programming
Module.’)
If the error continues to occur:
Please contact REXROTH Customer Service. Explain precisely under
what circumstances the error occurred. The firmware should be replaced.
F- 0309 NC cycle error
The initialization of communication between the drive and NC is not o.k.
Cause:
•
Data
loss.
•
Firmware update was executed. Previously, a different firmware or a
different version was loaded.
Remedy:
If possible, pre-select Parameter Mode and clear the error message.
Using S1, S2, and S3 on the programming module, execute a ’Load
parameters with default values.’ (See Chapter 4 ’S1 Key on Programming
Module.’)
If the error continues to occur:
Please contact REXROTH Customer Service. Explain precisely under
what circumstances the error occurred. The firmware should be replaced.
F- 0310 Parameter error
1. A parameter contains invalid data.
2. The contents of a parameter element is too large or too small.
3. The contents of a combination of parameters is not permitted.
Incorrect parameter combinations:
•
A100:
The motion type ’continuous’ or ’rotary table’ is
programmed and in Parameter CM00, a linear motor is
pre-selected.
•
A107:
The ’setup velocity’ is greater than A106 ’Maximum
Velocity.’
•
A111:
The ’switching threshold’ is greater than A105 ’Modulo
Value’ for A100 Motion Type ’Rotary Table.’
•
AA19:
The ’timeout duration’ is set in the parameters, but the
press function is not activated in AA12.
•
B009:
’Serial inputs/outputs’ are set in the parameters, but no
SIS protocol is pre-selected in B002.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......