ECODRIVE03-FL*-04VRS
Writing the User Program
6-7
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Axis-Related System Variables
The axis variables are read-only.
No.
Definition
V100
Absolute position of motor encoder (actual coordinate system)
V101
Position Command Value
V102
Reserved (Free)
V103
Lag Distance
V104
Actual Velocity in IU/s
V105
Processed Material Length [meters]
V106
Average Velocity in IU/s (see FUN command)
V107
Slip in Measuring Wheel Mode [%]
V108
Target Velocity in IU/s
V113
Distance from home position to processing location
Fig. 6-2: Axis System Variables
System Variable V000 "Cycle Counter 1":
The counter is incremented by 1 for each NC cycle. The value is output
as modulo-100000000 in NC cycles (1 NC cycle = 2 ms). The counter
cannot be cleared.
System Variable V001 "Cycle Counter 2“:
When the NC program has been started in Automatic Mode, the counter
is incremented by 1 for each NC cycle. The value is output as modulo-
100000000 in NC cycles. The counter cannot be cleared.
System Variable V002 "Current Program Instruction in Task 1":
The current status of the program instruction counter for Task 1.
System Variable V003 "Current Program Instruction in Task 2":
The current status of the program instruction counter for Task 2.
System Variable V004 "Current Program Instruction in Task 3":
The current status of the program instruction counter for Task 3.
System Variable V007 "Analog Input 1":
The input voltage (+/- 10 Volts) at the analog input is made available as a
standardized value of +/- 1in this variable.
System Variable V013 "Strokes per Minute":
With every positive change in the leading edge of the signal bit feed angle
monitoring (Parameter A116), the length of time since the previous
change in the leading edge is output. This time was available to the
previous positioning operation (stroke). This time is converted to
positioining operations (strokes) per minute. The result is output without
decimal places. The value is cleared only when restarting the system.
Note:
The function "Feed Angle Monitoring" (Parameter A116) must
be enabled.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......