12-34
Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C212 Invalid amplifier data
During drive initialization, the operating software accesses data from an
EEPROM in the drive controller. This error message is generated if the
attempt to read the data has failed.
Cause:
Defective hardware in the drive controller.
Remedy:
Replace the drive controller.
C213 Position data scaling error
Cause:
The drive-internal format of the position data is dependent on the motor
encoder and the encoder resolution. The factor for converting the position
data from the drive-internal format to the display format and vice versa is
outside of the possible range, because one of the following is true:
•
linear motor and rotary position scaling with respect to the motor, or
•
rotary motor and linear position scaling with respect to the motor, or
•
linear motor and modulo scaling is set, or
•
the detected factor for converting the position data from display
format to internal format or vice versa is not displayable.
Remedy:
•
Check parameters and make corrections.
•
Check for correct firmware.
•
Turn off and then on again. If this does not solve the problem:
•
Replace the unit.
C214 Velocity data scaling error
Cause:
The drive-internal format of the velocity data is dependent on the motor
encoder and the encoder resolution. The factor for converting the velocity
data from the drive-internal format to the display format and vice versa is
outside of the possible range.
Remedy:
•
Check parameters and make corrections.
•
Check for correct firmware.
•
Turn off and then on again. If this does not solve the problem:
•
Replace the unit.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......