6-58
Writing the User Program
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Axis is not homed:
•
Modes 0 and 1:
The axis cannot be homed using the SAC command. Beforehand, the
axis must be homed using the HOM command.
The error message "F- 03 05 - n. referenced" is issued.
See also Section 8, Functions/Homing.
•
Mode 9 :
No function. The program proceeds to the next instruction.
Axis is homed:
Parameters "A103, Negative travel limit" and "A104, Positive travel
limit" are valid. They remain in the initial coordinate system.
•
Mode 0 :
The target position is offset by the value in the SAC command.
(referenced to the initial coordinate system)
•
Mode 1 :
The target position is set to the value found in the SAC command.
•
Mode 9 :
No function. The program proceeds to the next instruction.
Sac_FLx1_AE.WMF
Fig. 6-27: How the SAC command works (linear)
Motion Type = 1
(linear)
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......