ECODRIVE03-FL*-04VRS
Interface
10-37
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Status 19
Hardware and firmware version
The status query:
? s X _ _ 1 9 _ C R L F
produces the following message, e.g.,:
X s 1 9 D K C 2 1 . 3 _ _ _ _ _ _ _ _ _ E C O D R 3 - F L P - x x V x x $ h h C R L F
Firmware version
max. 16 characters
Hardware version
max. 16 characters
Status 25
Two-digit diagnostic code with text output
see also TXT Command, Markers M6.37 – M6.39 and
Functional Description for 'Logic Task Controlled Diagnostic for Status
Message 25.'
The status query:
? s X _ _ 2 5 _ C R L F
produces the message:
Xs25_cc--------40 characters information-----$hh C R L F
cc = Current diagnostic code
Examples:
Xs25_8BAxis 1 Motor Has Overheated $hh CR LF
Xs25_02M: Feed Forward $hh CR LF
Overview of Error Messages:
Status Messages:
"02M: Feed Forward "
"0EPARAMETER MODE "
"17M: Feed Reverse "
"18Initializing System "
"1AA: C.Stop Active "
"3AFeed Rolls Open "
"48Stop Due To Interrupt Input! "
"99Control Error, See H1 Display "
Minor Error:
"13 Both Jogs High "
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......