8-62
Functions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Example 2:
SET
V500
=
600
Basic Variable 1 "Length“
SET
V501
=
610
Basic Variable 2 "Velocity“
SET
V502
=
620
Basic Variable 3 "Acceleration“
SET
V508
=
1
SET
V600
=
15
Product 1
Length
SET
V610
=
500
Product 1
Velocity
SET
V620
=
800
Product 1
Acceleration
SET
V601
=
20
Product 2
Length
SET
V611
=
700
Product 2
Velocity
SET
V621
=
550
Product 2
Acceleration
SET
V602
=
10
Product 3
Length
SET
V612
=
999
Product 3
Velocity
SET
V622
=
400
Product 3
Acceleration
Index
V509
Length
V500
Velocity
V501
Acceleration
V502
0
V600
V610
V620
1
V601
V611
V621
2
V602
V612
V622
3
V603
V613
V623
Fig. 8-39: Product Table, Example 2
SET
V509
= 2
Select Product 3
ACC
1 V502 999
Í
ACC 1 V620 999
Í
ACC 1 400 999
PSI
1 +V500 V501
Í
PSI 1 V600 V610
Í
POI 1 +010 999
It follows that:
V509 is used to access data for Product 3.
The value for acceleration is calculated from Variable
# 620+2*1 = 622.
The value for length is calculated from Variable
# 600+2*1 = 602.
The value for velocity is calculated from Variable
# 610+2*1 = 612.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......