5-6
Motor Configuration
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Setting Maximum Braking Time
The Maximum Braking time is used to monitor the braking time and
activate the motor holding brake if the theoretical braking time is
exceeded due to an error.
The motor holding brake is activated once the time (set in A119, Best
possible deceleration) since the start of the error reaction has elapsed.
Note:
The value in A119, Best possible deceleration must be set
so that the drive can come safely to a standstill from the
maximum speed at the maximum moment of inertia and
greatest load forces.
CAUTION
If the value in A119, Best possible deceleration is set
too low, then the error reaction is terminated and the
motor holding brake is activated at a speed greater than
10 RPM. Over time, this will damage the brake !
Connecting the Motor Holding Brake
See also Project Planning Specifications ECODRIVE 03
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......