ECODRIVE03-FL*-04VRS
Diagnostic Message Descriptions
12-7
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
F228 Excessive deviation
When the position loop is closed, the drive monitors whether it is able to
follow the specified command value. This is done by calculating a model
position value in the drive and comparing that value with the actual
feedback value. If the difference between the theoretical and actual
position values continually exceeds the value in Parameter A115,
Monitoring, the drive obviously cannot comply with the given command
value. This error is then generated.
Cause:
1.
The drive’s acceleration capacity has been exceeded.
2.
The axis is locked.
3.
Incorrect parameter values set in the drive parameters.
4.
Parameter A115, Monitoring set incorrectly.
Remedy:
For 1. Check program to see whether a value that is too low has been
entered in a MOM command.
For 2.
Check the mechanical system and eliminate jamming of the axis.
For 3.
Check the drive parameters (control loop settings).
For 4.
Set Parameter A115, Monitoring.
See also functional description for: "Position Control Loop Monitoring."
F229 Encoder 1 failure: Quadrant error
On the basis of faulty signals detected during the encoder evaluation, a
hardware error has been discovered in the interface being used for
encoder 1.
Cause:
1.
Defective encoder cable
2.
Electromagnetic interference on the encoder cable
3.
Defective encoder interface
4.
Defective drive controller
Remedy:
For 1.
Replace the encoder cable.
For 2. Keep the encoder cable well away from power cables. Use
shielded motor and encoder cables.
For 3.
Replace the encoder interface.
For 4.
Replace the drive controller.
F230 Max. signal frequency of encoder 1 exceeded
The signal frequency of encoder 1 (motor encoder) is checked to see
whether the max. permissible frequency of the encoder interface has
been exceeded.
If the frequency is higher than allowed, error F230, Max. signal
frequency of encoder 1 exceeded is generated. The “homed” output in
Parameter C010 is turned off.
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......