12-26
Diagnostic Message Descriptions
ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
E261 Continuous current limit prewarning
Digital drives are monitored via a continually operating temperature
model. Continuous current limiting is activated shortly after the thermal
load capacity reaches 100%.
At 90%, the continuous-current-limiting prewarning is issued prior to this
torque reduction.
Cause:
The drive controller was overloaded.
Remedy:
1.
Check the amplifier rating.
2.
Reduce acceleration.
3.
With systems which have been in use for long periods of time,
check to see if drive controller conditions have changed in regards
to:
•
friction
•
moved
mass
•
feed during processing
E263 Velocity command value > limit S-0-0091
Cause:
The maximum velocity stipulated was greater than the permissible
value.
Remedy:
The value is limited to that given in Parameter A106, Maximum velocity.
E267 Hardware synchronization defective
Drive control in the EcoX slave is synchronized to the EcoX bus via a
phase control loop. In order to enable the EcoX slave to synchronize to
the master, the master has to be in phase 3 or 4. The correct
synchronization function is monitored in the EcoX slave as of phase 4. If
the average divergence is greater than 5 µs, warning E267 is generated.
If controller enable has been set, error F267 is generated.
Cause:
1. The EcoX-Bus has not been parameterized in the EcoX master
2. The EcoX master is in phase 2
3. The EcoX bus is disturbed
4. The supply voltage of the EcoX master was cut off
Remedy:
1. Check
parameterization
2. Switch EcoX master to phase 3 or phase 4
3. Check EcoX bus
4. Check supply voltage of the EcoX master
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......