ECODRIVE03-FL*-04VRS
Command Communications
11-15
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Error Messages
If the slave detects an erroneous message, it generates an error
message. This message contains an error code as a 16-bit value that
indicates the source of the error. The error message has the following
structure:
Status Word
Service Data
C
E R
L
T
Length
Format
Data Data Data Data Data Data Data Data Data Data
S
0
0
1
d
0
1
0
d
0
0
1
0
1
0
1
1
y
y
x
x
x
x
x
x
x
x
Fig. 11-30: Structure of the Slave’s Error Message
The error bit is set and the R and toggle bits have the same value as the
bit set in the master. The error code indicates an internal error code. The
definition of the error code for internal errors is described as follows.
Error Code
yy (Hex)
Description
0x0085
The sum of the data in all of the collected fragments is too large.
0x0088
An internal error occurred during communication between the
fieldbus card and the drive controller.
0x008A
The index sent by the master is not present.
0x008B
The format is unknown.
0x008C
The length of the valid data indicated in the status word is longer
than the parameter channel length.
0x008D
Communication is not possible because the parameter channel
was configured with only 1 word.
0x0090
The format changed during collection of individual fragments.
0x0095
Additional data besides the index and subindex is present in a
read request.
0x0096
The internal SIS communication returned an error.
0x009A
This functionality has not been implemented.
0x009B
Switching between the "old" and "new" parameter channel is
occurring for sending / receiving data.
0x009C
The indicated subindex does not exist.
0x009D
The subindex is write-protected.
0x00F0
A timeout occurred during communication between the fieldbus
card and the drive controller.
0x01nn
nn = Error code for the "serial interface"
0x01FF
The length indicated by the slave for the data to be transmitted is
incorrect. ( >128)
Fig. 11-31: Error Codes
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......