ECODRIVE03-FL*-04VRS
Command Communications
11-13
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Status Word
Service Data
C
E R
L
T
Length
Format
Data Data Data Data Data Data Data Data Data Data
S
0
0
0
1
0
0
0
0
1
0
1
0
1
0
1
1
23
20
4E
30
30
30
30
20
4E
4F
#
_
N
0
0
0
0
_
N
O
Fig. 11-22: "Read Response" From the Slave (First Fragment)
Now, the master must switch the toggle bit to show the slave that it is
ready to receive new data. The R/W-Bit, the L-Bit, the length and the data
are not of interest, and are therefore not considered by the slave.
However, the master should set the bits as shown below.
Control Word
Service Data
C
E R
L
T
Length
Format
Data Data Data Data Data Data Data Data Data Data
M 0
0
0
1
0
1
0
1
0
0
0
0
1
0
1
1
x
x
x
x
x
x
x
x
x
x
Fig. 11-23: The Master Sends a "Read Request" for the Second Fragment
The slave responds with the second fragment, which contains the
remaining 4 bytes. The L-Bit is set, because the system is processing the
last fragment. In addition, the length is set accordingly.
Status Word
Service Data
C
E R
L
T
Length
Format
Data Data Data Data Data Data Data Data Data Data
S
0
0
0
1
0
1
0
1
0
1
0
0
1
0
1
1
50
20
20
20
x
x
x
x
x
x
P
_
_
_
Fig. 11-24: "Read Response" From the Slave (Last Fragment)
Writing a Value
In this example, an NC instruction is written:
•
# N0000 NOP
The master clears the R-Bit to signal a write operation. In this example,
the length of the operating datum is 12 bytes. Because only 5 data words
are available in the Service Data Channel, the request cannot be sent all
at once, but must be fragmented. Therefore, the L-Bit is not set; the
toggle bit was switched opposite of the previous state.
Control Word
Service Data
C
E R
L
T
Length
Format
Data Data Data Data Data Data Data Data Data Data
M 0
0
0
0
0
0
0
1
1
0
1
0
1
0
1
1
23
20
4E
30
30
30
30
20
4E
4F
#
_
N
0
0
0
0
_
N
O
Fig. 11-25: "Write Request" From the Master (First Fragment)
Содержание Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
Страница 18: ...XVI Table of Contents ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P ...
Страница 58: ...4 20 General Instructions for Start Up ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 187: ...ECODRIVE03 FL 04VRS Functions 8 41 DOK ECODR3 FL 04VRS FK01 EN P fp5007fj_AE WMF Fig 8 22 Control Loop ...
Страница 241: ...ECODRIVE03 FL 04VRS Parameters 9 29 DOK ECODR3 FL 04VRS FK01 EN P SIC_2_AE WMF Fig 9 12 Signal Control ...
Страница 348: ...11 18 Command Communications ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 418: ...13 4 Connectors ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 469: ...ECODRIVE03 FL 04VRS IDS Accessories 16 3 DOK ECODR3 FL 04VRS FK01 EN P IDS_mas_AE WMF Fig 16 5 IDS Dimensions ...
Страница 470: ...16 4 IDS Accessories ECODRIVE03 FL 04VRS DOK ECODR3 FL 04VRS FK01 EN P Notes ...
Страница 489: ......